Quick Start
Auto-Calibration: The sensor tares on power-up.
Plug in USB.
DO NOT blow into the mouthpiece.
Keep unit still for 2 seconds until "BASHWARE" clears.
Controls
ButtonAction:
Left / Right
Value Down / Up (Scroll)
Middle
Select / Edit / Enter
Menu Access: Click Middle button.
Settings
1. MIDI CH & CC
Middle: Toggle Channel (1-16) vs CC (0-127).
Left/Right: Adjust value.
2. Curve (Response)
Linear: Standard 1:1.
Log/Log+: High sensitivity (Woodwinds).
Inv/Inv+: Low sensitivity (Requires force).
3. Thresholds (Range)
Lower (Deadzone): Increase if notes stick when not blowing.
Upper (Max): Decrease to reach max volume with less breath.
Middle: Toggle Lower/Upper adjustment.
4. Flash Firmware
Enters update mode. Only use for upgrades.
Saving
Settings are NOT saved automatically.
Save: Hold Middle (1s) until "SAVED!" appears.
Back (No Save): Double-Click Middle.
Troubleshooting
Drift? Replug USB without touching mouthpiece.
Stuck Notes? Increase Lower Threshold.
Too Hard? Decrease Upper Threshold or use Log curve.